John Muir Medical Center Receiving Exceptional Performance From CHP System
Carson City, NV (PRWEB) July 08, 2011
It didn't take long for John Muir Medical Center to experience the exceptional efficiency of Elite Energy Systems' combined heat and power (CHP) solutions.
A study conducted nine months after the hospital's CHP system went online shows the application to be operating at 97 percent uptime. Thanks to the dependability of this system, John Muir is able to create enough heat and power for the entire 254-bed acute care facility on site, with minimal dependence on the utility grid.
From the months of September 2010 to May 2011, John Muir's four CHP units operated for 25,075 out of a potential 25,788 hours. During that time, the system generated well over 5.6 million kilowatt hours for the hospital.
This extraordinary performance is a testament to the efficiency of ELITE's EnviroGen® Energy Modules. John Muir's CHP system consists of four modules with a total electrical output of 907 kWe. Caterpillar G3400 Series naturally aspirated engines (3 x G3412NA and 1 x G3406NA) power the modules, driving Marathon synchronous generators at 1,800 RPM.
What makes this performance particularly notable is the fact that the system did not experience early hour problems typical of such installations. This is due to the quality of construction and the factory validation testing completed before the system was installed at the hospital. The CHP system generates heat as a byproduct of the generation process, which is captured by a Cention absorption chiller providing chilled water to the facility. The thermal output also provides for building heating, domestic hot water heating and/or boiler feed water heat/reheat.
The CHP application is controlled and monitored around the clock by ELITE's GenView™ Control System. GenView™ allows system administrators to remotely operate their CHP application from any computer. It tracks and logs system performance and notifies medical center staff and service personnel of pending maintenance intervals.
The addition of a CHP system is part of John Muir's ongoing commitment to sustainable and environmentally-friendly building practices. Combined heat and power is highly efficient, reduces carbon emissions and saves on energy costs.
About Elite Energy Systems, LLC Elite Energy Systems, LLC (ELITE) provides combined heat and power (CHP) solutions to commercial and industrial energy users looking to save on energy costs and reduce their emissions and carbon footprint. ELITE's modules are custom-built to meet specific energy needs and designed to provide an expedited return on investment with long-term energy savings. All CHP modules are powered by Caterpillar® natural gas and diesel engines. ELITE also provides customized control systems and offers custom fabrication, manufacturing, and packaging options. For more information, call (775) 246-8111 or visit www.eliteenergysys.com .
1800 Rpm Diesel Generator - News
For example, if we take the point circled on the fuel map at which the 140 Nm line intersects the 1800 rpm line we get: (140 x 1800)/9549 = 26.39 kW At this point on the graph, we can see the engine is burning 230 grams per kilowatt-hour (g/kWh).
Caterpillar G3400 Series naturally aspirated engines (3 x G3412NA and 1 x G3406NA) power the modules, driving Marathon synchronous generators at 1800 RPM. What makes this performance particularly notable is the fact that the system did not experience
Advantages and disadvantages of diesel generators
If you are considering buying a diesel generator for your power needs, it is also essential know the advantages and disadvantages of diesel generators. Diesel generator is the device most effective and economic power that can easily be placed in the most cost running. Advantages and disadvantages of its use will depend, general maintenance and performance on a normal basis. Some of the most essential advantages and disadvantages of diesel generators.
1800 Rpm Diesel Generator - Bookshelf
Diesel & gas turbine progress
Also included as a generator engine is the QD 90 rated at 50 hp at 1800 rpm continuous as a generator engine. "The range of Lister air-cooled, diesel ...Diesel Generator Auxiliary Systems and Instruments
For 1800 rpm rated engine speed if this governor is set at 5% droop this means ... of the system when several diesel generators are operating in parallel, ...Discrete-frequency and broadband noise radiation from diesel engine cooling fans
... diesel engine modified to accept a variable sheave speed electric drive. ... Sound Power Spectra due to the engine cooling fan operating at 1800 RPM, ...Efficiency of Demand Side Management Measures in Small Village Electrification Systems
The 1800 rpm units are 4-pole generators, which are recommended when more than 400 hours of operation per year are anticipated [39]. Diesel generators are ...Diesel Generators Design and Applications Training Reference
For 1800 rpm rated engine speed if this governor is set at 5% droop this means ... of the system when several diesel generators are operating in parallel, ...Detect Articles Directory
Generator 1800 Rpm-Generator 1800 Rpm Manufacturers ...
Choose Quality Generator 1800 Rpm Manufacturers, Suppliers, Exporters at Alibaba.com. ... Category: Electrical Equipment & Supplies | Diesel Generators ...
Used GENERATORS, A.C., DIESEL ENGINE DRIVEN, 60 CYCLE ...
Motors, generators, circuit breakers, gear reducers, generators, a.c., diesel engine driven, 60 cycle, 62,000 listings by 1100 suppliers
Diesel Generators
ST-3, 3kw Generator: Single Phase, 60 Hz, 230 / 115 V, 1800 RPM. ... This Diesel Generator-Set is made with Model 295 Diesel Engine and TFDX Model Generator. ...
Used diesel power generators available
Used diesel power generators available. Buy sell used diesel generator. ... Hertz, 1800 RPM, 12 Battery Volts -Powered by a 3.2L 3 Cylinder New Holland Diesel Engine ...
Mitsubishi 10-33 kW Diesel generators
7kW Isuzu powered diesel generator set. Running slow at 1800 RPM it will power 7000 watts continuously without problems or need for rest. ...